50 Part Number STH025 2/14
Ice Thickness Probe & Water Level Probe
Clean the probes using the following procedure.
1. Mix a solution of Manitowoc ice machine cleaner
and water (2 ounces of cleaner to 16 ounces of
water) in a container.
2. Clean all probe surfaces including all plastic parts
(do not use abrasives). Verify all surfaces are
clean. Thoroughly rinse probes with clean water.
3. Reinstall probe, then sanitize the ice machine and
bin/dispenser interior surfaces.