Part Number STH025 2/14 145
Suction Pressure High Checklist
Improper Installation
Refer to “Installation/Visual Inspection Checklist”
page 135
Discharge Pressure
Discharge pressure is too high and is affecting
suction pressure – refer to “Freeze Cycle
Discharge Pressure High Checklist” (page 142)
Improper Refrigerant Charge
Overcharged (also see “Freeze Cycle Discharge
Pressure High Checklist”
page 142)
Wrong type of refrigerant
Non condensable in system
Components
Harvest valve leaking
Harvest pressure solenoid valve leaking
TXV flooding
Defective compressor
Other
Non-Manitowoc components in system