Manitowoc I0320 Spécifications Page 106

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 272
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 105
106 Part Number STH025 2/14
4. Freeze
On Off Off
Cycles
Off then
On two
more
times
Off On On
May Cycle
On/Off
Until Ice Contact
w/Ice Thickness Probe
Harvest Sequence
5. Water Purge
On On On Off On On On
May Cycle
On/Off
Factory
Set at
45 Seconds
6. Harvest
Off On On Off Off On On
May Cycle
On/Off
Bin Switch
Activation
7. Automatic
Shut-Off
Off Off Off Off Off Off Off Off
Until 3 Minute Delay
Expires and Bin Switch
Re-closes
* NOT USED ON ALL MODELS
Self Contained Air & Water-Cooled Models (Continued)
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve(s)
Air
Pump(s)*
Water
Inlet
Valve
Water
Dump
Valve
Contactor
Coil
Compressor
Condenser
Fan Motor
Length
of Time
Vue de la page 105