Technician’s HandbookThis manual is updated as new information and models are released. Visit our website for the latest manual. www.manitowocice.comA
10 Part Number 80-1479-3 7/10HOW TO READ A MODEL NUMBERIce Cube SizesRegular1-1/8" x 1-1/8" x 7/8"2.86 x 2.86 x 2.22 cmDice7/8" x
100 Part Number 80-1479-3 7/10Freeze Cycle Suction Pressure_______ ______ _____1 minute Middle EndIf suction pressure is High or Low
Part Number 80-1479-3 7/10 101Discharge Line TemperatureRecord freeze cycle discharge line temperature at the end of the freeze cycle_________°F (°C)D
102 Part Number 80-1479-3 7/10Freeze Cycle Refrigeration System Operational Analysis TablesS MODELS FOUR EXPANSION VALVESOperational Analysis 1 2 3 4
Part Number 80-1479-3 7/10 103Freeze Cycle Discharge Pressure_____ ______ _____1 minute Middle EndIf discharge pressure is High or Low refer
104 Part Number 80-1479-3 7/10Harvest Valve Temperature Wait 5 minutes into the freeze cycle.Compare temperatures of compressor discharge line and har
Part Number 80-1479-3 7/10 105FREEZE CYCLE REFRIGERATION SYSTEM OPERATIONAL ANALYSIS TABLE PROCEDURESThe following is the procedures for completing ea
106 Part Number 80-1479-3 7/10Ice Production CheckThe amount of ice a machine produces directly relates to the operating water and air temperatures. T
Part Number 80-1479-3 7/10 107Weighing the ice is the only 100% accurate check. However, if the ice pattern is normal and the 1/8 in. thickness is mai
108 Part Number 80-1479-3 7/10Installation/Visual Inspection ChecklistInadequate Clearances• Check all clearances on sides, back and top.Ice machine i
Part Number 80-1479-3 7/10 109Water System ChecklistA water-related problem often causes the same symptoms as a refrigeration system component malfunc
Part Number 80-1479-3 7/10 11Model/Serial Number LocationThese numbers are required when requesting information from your local Manitowoc Distributor,
110 Part Number 80-1479-3 7/10Ice Formation PatternEvaporator ice formation pattern analysis is helpful in ice machine diagnostics.Analyzing the ice f
Part Number 80-1479-3 7/10 1112. Extremely Thin at Evaporator OutletThere is no ice, or a considerable lack of ice formation, at the outlet of the eva
112 Part Number 80-1479-3 7/10Analyzing Discharge Pressure in the Freeze Cycle1. Determine the ice machine operating conditions:Air temp. entering con
Part Number 80-1479-3 7/10 113FREEZE CYCLE DISCHARGE PRESSURE HIGH CHECKLISTImproper Installation• Refer to “Installation/Visual Inspection Checklist”
114 Part Number 80-1479-3 7/10FREEZE CYCLE DISCHARGE PRESSURELOW CHECKLISTImproper Installation• Refer to “Installation/Visual Inspection Checklist” (
Part Number 80-1479-3 7/10 115Analyzing Suction PressureThe suction pressure gradually drops throughout the Freeze cycle. The actual suction pressure
116 Part Number 80-1479-3 7/10Suction Pressure High ChecklistImproper Installation• Refer to “Installation/Visual Inspection Checklist” page 108Discha
Part Number 80-1479-3 7/10 117SUCTION PRESSURE LOW CHECKLISTImproper Installation• Refer to “Installation/Visual Inspection Checklist” (page 108)Disch
118 Part Number 80-1479-3 7/10Single Expansion Valve Ice Machines Comparing Evaporator Inlet and Outlet TemperaturesNOTE: This procedure will not work
Part Number 80-1479-3 7/10 119Multiple Expansion Valve Ice Machines Comparing Evaporator Inlet and Outlet TemperaturesThe temperatures of the suction
12 Part Number 80-1479-3 7/10Energy Efficient Ice MachineSerial BreaksSome specifications have changed with our release of more Energy Efficient machi
120 Part Number 80-1479-3 7/10Harvest Valve AnalysisSymptoms of a harvest valve remaining partially open during the freeze cycle can be similar to sym
Part Number 80-1479-3 7/10 1215. Record your findings on the table.Findings CommentsThe inlet of the harvest valve is cool enough to touch and the com
122 Part Number 80-1479-3 7/10Discharge Line Temperature AnalysisGENERALKnowing if the discharge line temperature is increasing, decreasing or remaini
Part Number 80-1479-3 7/10 123Water Regulating ValveProblem (Freeze Cycle)Valve not maintaining discharge pressure.• Valve incorrectly set, dirty or d
124 Part Number 80-1479-3 7/10Final AnalysisThe column with the highest number of check marks identifies the refrigeration problem.COLUMN 1 - HARVEST
Part Number 80-1479-3 7/10 125COLUMN 3 - TXV FLOODINGA loose or improperly mounted expansion valve bulb causes the expansion valve to flood. Check bul
126 Part Number 80-1479-3 7/10Harvest ProblemsDefinition of a harvest problem; At the end of a 3.5 minute harvest cycle the slab of ice is still conta
Part Number 80-1479-3 7/10 127SYMPTOM #3 ICE WILL NOT HARVEST, CUBES ARE NOT MELTEDYESYESYESNONONOYESIce Machine Will Not Harvest - Freeze Cycle is No
128 Part Number 80-1479-3 7/10YESYESYESYESYESYESYESNO NONONONONOSelf ContainedAir-cooled Condenser?Self ContainedWater-cooled Condenser?Fan cyclingcon
Part Number 80-1479-3 7/10 129SYMPTOM #3 - TRADITIONAL REMOTES ONLYRefer to Symptom #2 - Freeze Cycle Analysis ChartTraditional Remote Ice Machine - L
Part Number 80-1479-3 7/10 13Ice Machine Warranty InformationOWNER WARRANTY REGISTRATION CARDWarranty coverage begins the day the ice machine is insta
130 Part Number 80-1479-3 7/10Refer to Sequence ofOperation & Wiring DiagramsYESYESYESNONONOYESNOYESIs harvest valve energized?Is head pressure hi
Part Number 80-1479-3 7/10 131SYMPTOM #4 WILL NOT HARVEST, MELTED CUBESLevel Ice MachineRefer toDump ValveDiagnosticsIs water flowing over the evapora
132 Part Number 80-1479-3 7/10Refer to Symptom #2 Freeze Cycle OperationalAnalysis TableRefer to Heavily ScaledCleaning ProcedureDischarge line temper
Part Number 80-1479-3 7/10 133This Page Intentionally Left Blank
134 Part Number 80-1479-3 7/10This Page Intentionally Left Blank
Part Number 80-1479-3 7/10 135Component Check ProceduresElectrical ComponentsMAIN FUSEFUNCTIONThe control board fuse stops ice machine operation if el
136 Part Number 80-1479-3 7/10ICE/OFF/CLEAN TOGGLE SWITCHFUNCTIONThe switch is used to place the ice machine in ICE, OFF or CLEAN mode of operation.SP
Part Number 80-1479-3 7/10 137BIN SWITCHFUNCTIONMovement of the water curtain/ice dampers control bin switch operation. The bin switch has two main fu
138 Part Number 80-1479-3 7/10SYMPTOMSBin Switch Fails Open• The ice machine will not start with the toggle switch in the ice position, but runs norma
Part Number 80-1479-3 7/10 139Water Curtain/Ice Damper Removal NotesThe water curtain must be on (bin switch closed) to start ice making. While a Free
14 Part Number 80-1479-3 7/10COMMERCIAL WARRANTY COVERAGEManitowoc Ice, (hereinafter referred to as the "COMPANY") warrants for a period of
140 Part Number 80-1479-3 7/10CLEANING THE ICE THICKNESS OR WATER LEVEL PROBEClean the probes using the following procedure.1. Mix a solution of Manit
Part Number 80-1479-3 7/10 141WATER LEVEL CONTROL CIRCUITRYThe water level probe circuit can be monitored by watching the water level light. The water
142 Part Number 80-1479-3 7/10Diagnosing Water Level Control CircuitryPROBLEM: WATER TROUGH OVERFILLING DURING THE FREEZE CYCLEStep 1 Start a new Fr
Part Number 80-1479-3 7/10 143WATER TROUGH OVERFILLING CONTINUEDStep 3. Jumper Wire Connected from Control Board Terminal to GroundIs WaterFlowinginto
144 Part Number 80-1479-3 7/10PROBLEM: WATER WILL NOT RUN INTO THE SUMP TROUGH DURING THE FREEZE CYCLEStep 1 Verify water is supplied to the ice mac
Part Number 80-1479-3 7/10 145Step 3 Disconnect the water level probe from the water level probe terminal on the control board.ImportantFor the tes
146 Part Number 80-1479-3 7/10ICE THICKNESS PROBE (HARVEST INITIATION)HOW THE PROBE WORKSManitowoc’s electronic sensing circuit does not rely on refri
Part Number 80-1479-3 7/10 147MAXIMUM FREEZE TIMEThe control system includes a built-in safety which will automatically cycle the ice machine into har
148 Part Number 80-1479-3 7/10Diagnosing Ice Thickness Control CircuitryPROBLEM: ICE MACHINE DOES NOT CYCLE INTO HARVEST WHEN WATER CONTACTS THE ICE T
Part Number 80-1479-3 7/10 149PROBLEM: ICE MACHINE CYCLES INTO HARVEST BEFORE WATER CONTACT WITH THE ICE THICKNESS PROBEStep 1 Bypass the freeze tim
Part Number 80-1479-3 7/10 15The foregoing warranty shall not apply to (1) any part or assembly that has been altered, modified, or changed; (2) any p
150 Part Number 80-1479-3 7/10HARVEST CYCLE CIRCUITRYThe water level probe does not control the water inlet valve during the harvest cycle. During the
Part Number 80-1479-3 7/10 151HARVEST ASSIST AIR PUMPFUNCTIONThe air pump breaks the vacuum between the sheet of ice and the evaporator which results
152 Part Number 80-1479-3 7/10Compressor Electrical DiagnosticsThe compressor does not start or will trip repeatedly on overload.Check Resistance (Ohm
Part Number 80-1479-3 7/10 153CHECK MOTOR WINDINGS TO GROUNDCheck continuity between all three terminals and the compressor shell or copper refrigerat
154 Part Number 80-1479-3 7/10DIAGNOSING START COMPONENTSIf the compressor attempts to start, or hums and trips the overload protector, check the star
Part Number 80-1479-3 7/10 155RelayThe relay has a set of contacts that connect and disconnect the start capacitor from the compressor start winding.
156 Part Number 80-1479-3 7/10PTCRThe PTCR allows current to flow through the start winding at compressor startup. Current flow heats the ceramic disc
Part Number 80-1479-3 7/10 157PTCR Operation Check1. Visually inspect the PTCR. Check for signs of physical damage.NOTE: The PTCR case temperature may
158 Part Number 80-1479-3 7/10Refrigeration ComponentsHIGH PRESSURE CUTOUT (HPCO) CONTROLFUNCTIONStops the ice machine if subjected to excessive high-
Part Number 80-1479-3 7/10 159FAN CYCLE CONTROLSelf-Contained Air-Cooled Models OnlyFUNCTIONCycles the fan motor on and off to maintain proper operati
16 Part Number 80-1479-3 7/10RESIDENTIAL ICE MACHINE LIMITED WARRANTYWHAT DOES THIS LIMITED WARRANTY COVER?Subject to the exclusions and limitations b
160 Part Number 80-1479-3 7/10WATER REGULATING VALVESelf-Contained Water-Cooled Models OnlyFUNCTIONThe water regulating valve maintains the freeze cyc
Part Number 80-1479-3 7/10 161HARVEST PRESSURE REGULATING (HPR) SYSTEM REMOTES ONLYGENERALThe harvest pressure regulating (H.P.R.) system includes:• H
162 Part Number 80-1479-3 7/10FREEZE CYCLEThe H.P.R. system is not used during the freeze cycle. The H.P.R. solenoid is closed (de-energized), prevent
Part Number 80-1479-3 7/10 1633. Freeze time normal? (Refer to Cycle Times/Refrigerant Pressures/24 Hour Ice Production Charts page 191)Shorter freeze
164 Part Number 80-1479-3 7/10HEAD PRESSURE CONTROL VALVEManitowoc remote systems require head pressure control valves with special settings. Replace
Part Number 80-1479-3 7/10 1655. Using the information gathered, refer to the chart below.NOTE: A head pressure control valve that will not bypass, wi
166 Part Number 80-1479-3 7/10FAN CYCLE CONTROL VS. HEAD PRESSURE CONTROL VALVEA fan cycle control cannot be used in place of a head pressure control
Part Number 80-1479-3 7/10 167LOW PRESSURE CUTOUT (LPCO) CONTROL(S3300 Only)FUNCTIONSignals the control board to energize and de-energize the ice mach
168 Part Number 80-1479-3 7/10HARVEST PRESSURE SOLENOID VALVE(S3300 Only)FUNCTIONTransfers refrigerant from the high side to the low side during the h
Part Number 80-1479-3 7/10 169Refrigerant Recovery/EvacuationNORMAL SELF-CONTAINED MODEL PROCEDURESDo not purge refrigerant to the atmosphere. Capture
Part Number 80-1479-3 7/10 17WHAT ARE MANITOWOC ICE’S OBLIGATIONS UNDER THIS LIMITED WARRANTY?If a defect arises and Manitowoc receives a valid warran
170 Part Number 80-1479-3 7/10Self-Contained Recovery/Evacuation1. Place the toggle switch in the OFF position.2. Install manifold gauges, scale and r
Part Number 80-1479-3 7/10 171Self-Contained Charging Procedures1. Be sure the toggle switch is in the OFF position.ImportantThe ch arge is critical o
172 Part Number 80-1479-3 7/102. Close the vacuum pump valve, the low side service valve, and the low side manifold gauge valve.3. Open the high side
Part Number 80-1479-3 7/10 173NORMAL REMOTE MODEL PROCEDURESRefrigerant Recovery/EvacuationDo not purge refrigerant to the atmosphere. Capture refrige
174 Part Number 80-1479-3 7/10NOTE: Manitowoc recommends using an access valve core removal and installation tool on the discharge line quick-connect
Part Number 80-1479-3 7/10 175REMOTERECOVERY/EVACUATIONCONNECTIONS
176 Part Number 80-1479-3 7/10Remote Charging Procedures1. Be sure the toggle switch is in the OFF position.2. Close the vacuum pump valve, the low an
Part Number 80-1479-3 7/10 177xxxSCHRAEDER FITTINGQUICK CONNECTDISCHARGE LINECONTROL VALVEHEAD PRESSUREREMOTE CONDENSERCLOSEDCLOSEDSCALERECOVERY UNITV
178 Part Number 80-1479-3 7/10System Contamination Clean-UpGeneralThis section describes the basic requirements for restoring contaminated systems to
Part Number 80-1479-3 7/10 179Contamination Cleanup ChartSymptoms/FindingsRequired Cleanup ProcedureNo symptoms or suspicion of contaminationNormal ev
18 Part Number 80-1479-3 7/10WHAT IS NOT COVERED? This limited warranty does not cover, and you are solely responsible for the costs of: (1) periodic
180 Part Number 80-1479-3 7/10CLEANUP PROCEDUREMild System Contamination1. Replace any failed components.2. If the compressor is good, change the oil.
Part Number 80-1479-3 7/10 181Severe System Contamination1. Remove the refrigerant charge.2. Remove the compressor.3. Disassemble the harvest solenoid
182 Part Number 80-1479-3 7/1010. Follow the normal evacuation procedure, except replace the evacuation step with the following:A. Pull vacuum to 1000
Part Number 80-1479-3 7/10 183REPLACING PRESSURE CONTROLS WITHOUT REMOVING REFRIGERANT CHARGEThis procedure reduces repair time and cost. Use it when
184 Part Number 80-1479-3 7/10SV1406USING PINCH-OFF TOOL
Part Number 80-1479-3 7/10 185SpecificationsMAIN FUSEThe main fuse is 250 Volt, 7 amp.FAN CYCLE CONTROL(Self-Contained Air-Cooled Models Only)HIGH PRE
186 Part Number 80-1479-3 7/10FILTER-DRIERSThe filter-driers used on Manitowoc ice machines are manufactured to Manitowoc specifications.The differenc
Part Number 80-1479-3 7/10 187TOTAL SYSTEM REFRIGERANT CHARGENOTE: All machines listed use R-404A refrigerant.ImportantThis information is for referen
188 Part Number 80-1479-3 7/10S1000 Before 110697023 36 oz. 26 oz. 8.5 lb. 2 lb. 10.5 lb.S1000 After 110697023 34 oz. 28 oz. 8.5 lb. 2 lb. 10.5 lb.S12
Part Number 80-1479-3 7/10 189This Page Intentionally Left Blank
Part Number 80-1479-3 7/10 19IN NO EVENT SHALL MANITOWOC OR ANY OF ITS AFFILIATES BE LIABLE TO THE CONSUMER OR ANY OTHER PERSON FOR ANY INCIDENTAL, CO
190 Part Number 80-1479-3 7/10This Page Intentionally Left Blank
Part Number 80-1479-3 7/10 191ChartsCycle Times/24-Hour Ice Production/Refrigerant Pressure ChartsThese charts are used as guidelines to verify correc
192 Part Number 80-1479-3 7/10S300 SERIESS300AAll Self-Contained Air-cooled Models Before Serial Number 110704351Characteristics may vary depending on
Part Number 80-1479-3 7/10 193S300AAll Self-Contained Air-cooled Models After Serial Number 110704351Characteristics may vary depending on operating c
194 Part Number 80-1479-3 7/10S300WAll Self-Contained Water-cooled Models Before Serial Number 110704351Characteristics may vary depending on operatin
Part Number 80-1479-3 7/10 195S300WAll Self-Contained Water-cooled Models After Serial Number 110704351Characteristics may vary depending on operating
196 Part Number 80-1479-3 7/10S320 SERIESS300AAll Self-Contained Air-Cooled ModelsCharacteristics may vary depending on operating conditions.CYCLE TIM
Part Number 80-1479-3 7/10 197S320 SeriesAll Self-Contained Water-Cooled ModelsCharacteristics may vary depending on operating conditions.CYCLE TIMESF
198 Part Number 80-1479-3 7/10S420 SERIESS420AAll Self-Contained Air-cooled Models Before Serial Number110667970Characteristics may vary depending on
Part Number 80-1479-3 7/10 199S420AAll Self-Contained Air-cooled Models After Serial Number 110667970Characteristics may vary depending on operating c
20 Part Number 80-1479-3 7/10This Page Intentionally Left Blank
200 Part Number 80-1479-3 7/10S420WAll Self-Contained Water-cooled Models Before Serial Number 110667970Characteristics may vary depending on operatin
Part Number 80-1479-3 7/10 201S420WAll Self-Contained Water-cooled Models After Serial Number 110667970Characteristics may vary depending on operating
202 Part Number 80-1479-3 7/10S450 SERIESS450AAll Self-Contained Air-cooled Models Before Serial Number 110670157Characteristics may vary depending on
Part Number 80-1479-3 7/10 203S450AAll Self-Contained Air-cooled Models After Serial Number 110670157Characteristics may vary depending on operating c
204 Part Number 80-1479-3 7/10S450WAll Self-Contained Water-cooled Models Before Serial Number 110670157Characteristics may vary depending on operatin
Part Number 80-1479-3 7/10 205S450WAll Self-Contained Water-cooled Models After Serial Number 110670157Characteristics may vary depending on operating
206 Part Number 80-1479-3 7/10S500 SERIESS500AAll Self-Contained Air-cooled Models Before Serial Number 110684316Characteristics may vary depending on
Part Number 80-1479-3 7/10 207SD0502A Dice Cube, Self-Contained Air-cooled After Serial Number Characteristics may vary depending on operating conditi
208 Part Number 80-1479-3 7/10SY0504AHalf Dice Cube, Self-Contained Air-cooled After Serial Number 110684316Characteristics may vary depending on oper
Part Number 80-1479-3 7/10 209S500WAll Self-Contained Water-cooled Models Before Serial Number 110684316Characteristics may vary depending on operatin
Part Number 80-1479-3 7/10 21InstallationLocation of Ice MachineThe location selected for the ice machine head section must meet the following criteri
210 Part Number 80-1479-3 7/10SD0503WDice Cube, Self-Contained Water-cooled Models After Serial Number 110684316Characteristics may vary depending on
Part Number 80-1479-3 7/10 211SY0505W Half Dice Cube, Self-Contained Water-cooled After Serial Number 110684316Characteristics may vary depending on o
212 Part Number 80-1479-3 7/10S500NAll Remote Air-cooled Condenser Models Before Serial Number 110684316Characteristics may vary depending on operatin
Part Number 80-1479-3 7/10 213SD0592NDice Cube, Remote Air-cooled Condenser Models After Serial Number 110684316Characteristics may vary depending on
214 Part Number 80-1479-3 7/10SY0594NHalf Dice Cube, Remote Air-cooled Condenser Models After Serial Number 110684316Characteristics may vary dependin
Part Number 80-1479-3 7/10 215S600 SERIESS600AAll Self-Contained Air-Cooled ModelsCharacteristics may vary depending on operating conditions.CYCLE TIM
216 Part Number 80-1479-3 7/10S600WAll Self-Contained Water-Cooled ModelsCharacteristics may vary depending on operating conditions.CYCLE TIMESFreeze
Part Number 80-1479-3 7/10 217S600NAll Remote Air-Cooled Condenser ModelsCharacteristics may vary depending on operating conditions.CYCLE TIMESFreeze
218 Part Number 80-1479-3 7/10S850 SERIESS850AAll Self-Contained Air-Cooled Models Before Serial Number 110683282Characteristics may vary depending on
Part Number 80-1479-3 7/10 219SD0852ADice Cube, Self-Contained Air-Cooled Models After Serial Number 110683282Characteristics may vary depending on op
22 Part Number 80-1479-3 7/10Ice Machine Clearance RequirementsS300Self-Contained Air-CooledSelf-Contained Water-CooledTop/Sides 16" (40.6 cm) 8&
220 Part Number 80-1479-3 7/10SY0854AHalf Dice Cube, Self-Contained Air-Cooled Models After Serial Number 110683282Characteristics may vary depending
Part Number 80-1479-3 7/10 221S850WAll Self-Contained Water-Cooled Models Before Serial Number 110683282Characteristics may vary depending on operatin
222 Part Number 80-1479-3 7/10SD0853WDice Cube, Self-Contained Water-Cooled Models After Serial Number 110683282Characteristics may vary depending on
Part Number 80-1479-3 7/10 223SY0855WHalf Dice Cube, Self-Contained Water-Cooled Models After Serial Number 110683282Characteristics may vary dependin
224 Part Number 80-1479-3 7/10S850N Remote Air-cooled CondenserAll Remote Condenser Air-Cooled Before Serial Number 110682385Characteristics may vary
Part Number 80-1479-3 7/10 225SD0892N Dice Cube, Remote Condenser Air-Cooled After Serial Number 110682385Characteristics may vary depending on operat
226 Part Number 80-1479-3 7/10SY0894N Half Dice Cube, Remote Condenser Air-Cooled After Serial Number 110682385Characteristics may vary depending on o
Part Number 80-1479-3 7/10 227S1000 SERIESS1000AAll Self-Contained Air-cooled Before Serial Number 110697023Characteristics may vary depending on oper
228 Part Number 80-1479-3 7/10SD1002ADice Cube, Self-Contained Air-cooled After Serial Number 110697023Characteristics may vary depending on operating
Part Number 80-1479-3 7/10 229SY1004AHalf Dice Cube, Self-Contained Air-cooled After Serial Number 110697023Characteristics may vary depending on oper
Part Number 80-1479-3 7/10 23Ice Machine Heat of RejectionSeries Ice MachineHeat of RejectionAir Conditioning*PeakS300 3,800 6,000S320 3,800 6,000S420
230 Part Number 80-1479-3 7/10S1000WAll Self-Contained Water-cooled Before Serial Number 110697023Characteristics may vary depending on operating cond
Part Number 80-1479-3 7/10 231SD1003WDice Cube, Self-Contained Water-cooled After Serial Number 110697023Characteristics may vary depending on operati
232 Part Number 80-1479-3 7/10SY1005WHalf Dice Cube, Self-Contained Water-cooled After Serial Number 110697023Characteristics may vary depending on op
Part Number 80-1479-3 7/10 233S1000NAll Remote Condenser Air-cooled Before Serial Number 110697023Characteristics may vary depending on operating cond
234 Part Number 80-1479-3 7/10SD1092NDice Cube, Remote Condenser Air-cooled After Serial Number 110697023Characteristics may vary depending on operati
Part Number 80-1479-3 7/10 235SY1094NHalf Dice Cube, Remote Condenser Air-cooled After Serial Number 110697023Characteristics may vary depending on op
236 Part Number 80-1479-3 7/10S1200 SERIESS1200AAll Self-Contained Air-cooled Before Serial Number 110697023Characteristics may vary depending on oper
Part Number 80-1479-3 7/10 237SD1202A Dice Cube, Self-Contained Air-cooled After Serial Number 110697023Characteristics may vary depending on operatin
238 Part Number 80-1479-3 7/10SY1204AHalf Dice Cube, Self-Contained Air-cooled After Serial Number 110697023Characteristics may vary depending on oper
Part Number 80-1479-3 7/10 239S1200WAll Self-Contained Water-cooled Before Serial Number 110697023Characteristics may vary depending on operating cond
24 Part Number 80-1479-3 7/10REMOTE CONDENSER LINE SET INSTALLATIONIce MachineRemote Single Circuit CondenserLine Set*S500 JC0495RT-20-R404ART-35-R404
240 Part Number 80-1479-3 7/10SD1203WDice Cube, Self-Contained Water-cooled After Serial Number 110697023Characteristics may vary depending on operati
Part Number 80-1479-3 7/10 241SY1205WHalf Dice Cube, Self-Contained Water-cooled After Serial Number 110697023Characteristics may vary depending on op
242 Part Number 80-1479-3 7/10S1400 SERIESS1400 Self-contained air-cooledAll Self-Contained Air-cooled with a Manufacture Date Before 0905 (May 2009)C
Part Number 80-1479-3 7/10 243SD1402A Dice Cube, Self-Contained Air-Cooled With a Manufacture Date of 0905 (May 2009) or Later Characteristics may var
244 Part Number 80-1479-3 7/10SY1404A Half Dice Cube, Self-Contained Air-Cooled With a Manufacture Date of 0905 (May 2009) or Later Characteristics ma
Part Number 80-1479-3 7/10 245S1400 Self-contained Water-cooledAll Self-Contained Water-cooled with a Manufacture Date Before 0711 (November 2007)Char
246 Part Number 80-1479-3 7/10SD1403W Dice Cube, Self-Contained Water-Cooled With a Manufacture Date From 0711 to 0905 (November 2007 to May 2009)Char
Part Number 80-1479-3 7/10 247SY1405WHalf Dice Cube, Self-Contained Water-Cooled With a Manufacture Date From 0711 to 0905 (November 2007 to May 2009)
248 Part Number 80-1479-3 7/10SD1403W Dice Cube, Self-Contained Water-Cooled With a Manufacture Date of 0905 (May 2009) or LaterCharacteristics may va
Part Number 80-1479-3 7/10 249SY1405W Half Dice Cube, Self-Contained Water-Cooled With a Manufacture Date of 0905 (May 2009) or LaterCharacteristics m
Part Number 80-1479-3 7/10 25CALCULATING REMOTE CONDENSER INSTALLATION DISTANCESNOTE: Manitowoc warrants only complete new and unused remote packages.
250 Part Number 80-1479-3 7/10S1400 Remote Air-cooled CondenserAll Remote Condenser Air-cooled with a Manufacture Date Before 0905 (May 2009)Character
Part Number 80-1479-3 7/10 251SD1492N Dice Cube, Remote Condenser Air-Cooled With a Manufacture Date of 0905 (May 2009) or LaterCharacteristics may va
252 Part Number 80-1479-3 7/10SY1494N Half Dice Cube, Remote Condenser Air-Cooled With a Manufacture Date of 0905 (May 2009) or LaterCharacteristics m
Part Number 80-1479-3 7/10 253S1600 SERIESS1600AAll Self-Contained Air-cooledCharacteristics may vary depending on operating conditions.CYCLE TIMESFre
254 Part Number 80-1479-3 7/10S1600WAll Self-Contained Water-cooledCharacteristics may vary depending on operating conditions.CYCLE TIMESFreeze Time +
Part Number 80-1479-3 7/10 255S1600NAll Remote Air-cooled CondenserCharacteristics may vary depending on operating conditions.CYCLE TIMESFreeze Time +
256 Part Number 80-1479-3 7/10S1800 SERIESS1800 Self-contained air-cooledAll Self-Contained Air-cooled with a Manufacture Date Before 0910 (October 20
Part Number 80-1479-3 7/10 257SD1802ADice Cube, Self-Contained Air-cooled with a Manufacture Date After 0910 (October 2009)Characteristics may vary de
258 Part Number 80-1479-3 7/10SY1804AHalf Dice Cube, Self-Contained Air-cooled with a Manufacture Date After 0910 (October 2009)Characteristics may va
Part Number 80-1479-3 7/10 259S1800 Self-Contained Water-CooledAll Self-Contained Water-cooled with a Manufacture Date Before 0910 (October 2009)Chara
26 Part Number 80-1479-3 7/10Calculated Line Set DistanceThe maximum calculated distance is 150' (45.7 m).Line set rises, drops, horizontal runs
260 Part Number 80-1479-3 7/10SD1803WDice Cube, Self-Contained Water-cooled with a Manufacture Date After 0910 (October 2009)Characteristics may vary
Part Number 80-1479-3 7/10 261SY1805WHalf Dice Cube, Self-Contained Water-cooled with a Manufacture Date After 0910 (October 2009)Characteristics may
262 Part Number 80-1479-3 7/10S1800 Remote Air-cooled CondenserAll Remote Condenser Air-cooled with a Manufacture Date Before 0910 (October 2009)Chara
Part Number 80-1479-3 7/10 263SD1892NDice Cube, Remote Condenser Air-cooled with a Manufacture Date After 0910 (October 2009)Characteristics may vary
264 Part Number 80-1479-3 7/10SY1894NHalf Dice Cube, Remote Condenser Air-cooled with a Manufacture Date After 0910 (October 2009)Characteristics may
Part Number 80-1479-3 7/10 265S3300 SERIESSD3303W Self-Contained Water-CooledAll Dice Cube, Self-Contained Water-cooled Ice MachinesCharacteristics ma
266 Part Number 80-1479-3 7/10SY3305WAll Half Dice Cube, Self-Contained Water-cooled Ice MachinesCharacteristics may vary depending on operating condi
Part Number 80-1479-3 7/10 267DiagramsWiring DiagramsThe following pages contain electrical wiring diagrams. Be sure you are referring to the correct
268 Part Number 80-1479-3 7/10WIRING DIAGRAMS BEFORE ENERGY EFFICIENT & ENERGYSTAR MACHINESS320Self Contained - 1 Phase(48)RSCCLEANOFFICEBINSWITCH
Part Number 80-1479-3 7/10 269S300/S420/S450/S500 (after serial number 110074051) - Self Contained - 1 PhaseSV3137A(89)(55)(88)(42)High Pressure Cutou
Part Number 80-1479-3 7/10 27Maximum Line Set Distance FormulaStep 1 Measured Rise ____ X 1.7 = ______Calculated Rise(35 ft. Max)Step 2 Measured D
270 Part Number 80-1479-3 7/10S500 (before serial number 110074051)S600/S850/S1000/S1200- Self Contained- 1 PhaseSV3130(89) (55)(88)(42)High Pressure
Part Number 80-1479-3 7/10 271S850/S1000/S1200 - Self Contained - 3 PhaseSV3131(89)(55)(88)(42)High Pressure CutoutWater ValveHarvest ValveDump ValveW
272 Part Number 80-1479-3 7/10S500 Danfoss Compressor (after serial number 110074051) - Remote - 1 Phase(49)(47)COMPRESSOROVERLOAD INTERNAL{230V 50/60
Part Number 80-1479-3 7/10 273S500 (before serial number 110074051)/S600/S850/S1000/S1200 - Remote - 1 PhaseSV3158(89) (55)(88)(42)High Pressure Cutou
274 Part Number 80-1479-3 7/10S850/S1000/S1200 - Remote - 3 PhaseSV3131(89) (55)(88)(42)High Pressure CutoutWater ValveHarvest ValveDump ValveWater Pu
Part Number 80-1479-3 7/10 275S1400/S1600/S1800 - Self-Contained - 1 Phase(2)(1)RSCLEANOFFICE RUNCAPACITOR(50)(45)R(46)PTCR(AIR COOLED ONLY)FAN MOTOR
276 Part Number 80-1479-3 7/10S1400/S1600/S1800 - Self-Contained - 3 Phase(42)CONTROL BOARDCLEANOFFICEBINSWITCH(8)LOW D.C.VOLTAGEPLUGCONTACTORCOIL(56)
Part Number 80-1479-3 7/10 277S1400/S1600/S1800 - Remote - 1 PhaseR(45)R(46)PTCR(44)(59)CLEANLEFT BINRIGHT BINRMT BINWTR PROBEICE PROBEHARVSL-1SL-2(6)
278 Part Number 80-1479-3 7/10S1400/S1600/S1800 - Remote - 3 Phase(42)ICE THICKNESSPROBEWATER LEVELPROBEHIGH PRESSURECUTOUT(89)(88)T3L2L3COMPRESSORT1T
Part Number 80-1479-3 7/10 279WIRING DIAGRAMS FOR ENERGY EFFICIENT & ENERGYSTAR MACHINESS300/S420/S450/S500Self-Contained - 1 PhaseCaution: Discon
28 Part Number 80-1479-3 7/10CONNECTING A LINE SET1. Remove the dust caps from the line set, condenser and ice machine.2. Apply refrigeration oil to t
280 Part Number 80-1479-3 7/10S600/S850/S1000/S1200Self-Contained - 1 PhaseCaution: Disconnect Power Before Working on Electrical CircuitryL1HIGH PRES
Part Number 80-1479-3 7/10 281S850/S1000/S1200Self-Contained - 3 PhaseCaution: Disconnect Power Before Working on Electrical CircuitryL1HIGH PRESSUREC
282 Part Number 80-1479-3 7/10S1400/S1800Self-Contained - 1 Phase(2)(1)RSCLEANOFFICE RUNCAPACITOR(50)(45)R(46)3 TERMINAL PTCR(AIR COOLED ONLY)FAN MOT
Part Number 80-1479-3 7/10 283S1400/S1800Self-Contained - 3 Phase(42)CONTROL BOARDCLEANOFFICEBINSWITCH(8)LOW D.C.VOLTAGEPLUGCONTACTORCOIL(56)TERMINATE
284 Part Number 80-1479-3 7/10S3300Water-Cooled - 3 phaseAIR PUMP 4AIR PUMP 3AIR PUMP 2AIR PUMP 1HARVESTSOLENOID 4HARVESTSOLENOID 3HARVESTSOLENOID 2HA
Part Number 80-1479-3 7/10 285S500Remote - 1 PhaseCaution: Disconnect Power Before Working on Electrical CircuitryL1HIGH PRESSURECUTOUT(89)(88)CONTROL
286 Part Number 80-1479-3 7/10S600/S850/S1000/S1200Remote - 1 PhaseCaution: Disconnect Power Before Working on Electrical CircuitryL1HIGH PRESSURECUTO
Part Number 80-1479-3 7/10 287S850/S1000/S1200Remote - 3 PhaseCaution: Disconnect Power Before Working on Electrical CircuitryL1HIGH PRESSURECUTOUT(89
288 Part Number 80-1479-3 7/10S1400/S1800Remote - 1 Phase(59)CLEANLEFT BINRIGHT BINRMT BINWTR PROBEICE PROBEHARVSL-1SL-2(6)(2)(1)(25)(26)L2(9)(8)(42)C
Part Number 80-1479-3 7/10 289S1400/S1800Remote - 3 Phase(42)ICE THICKNESSPROBEWATER LEVELPROBEHIGH PRESSURECUTOUT(89)(88)T3L2L3COMPRESSORT1T2CONTACTS
Part Number 80-1479-3 7/10 29Component IdentificationS Model Single Evaporator ModelsWATER CURTAINCONTROL BOXWATER DISTRIBUTION TUBETOGGLE SWITCHWATER
290 Part Number 80-1479-3 7/10Electronic Control BoardSingle and Twin Evaporator Without Test ButtonN 115VL2 208-230VPRIMARY POWERSUPPLYAC LINE VOLTAG
Part Number 80-1479-3 7/10 291Single and Twin Evaporator With Test ButtonN 115VL2 208-230VPRIMARY POWERSUPPLYAC LINE VOLTAGEELECTRICAL PLUGMAIN FUSE(7
292 Part Number 80-1479-3 7/10Quad Evaporator Ice MachinesICE PROBEWATER LEVEL PROBEHARVEST VALVESFUSE 7ACLEAN (YELLOW)HARVEST (RED)WATER LEVEL (GREEN
Part Number 80-1479-3 7/10 293Refrigeration Tubing SchematicsSELF-CONTAINED AIR- ORWATER -COOLED MODELSS300/S320/S420/S450/S500/S600/S850/S1000/S1200S
294 Part Number 80-1479-3 7/10S3300xxxxxEVAPORATOR 1EVAPORATOR 2EVAPORATOR 3 EVAPORATOR 4WATER-COOLEDCONDENSERSCROLLCOMPRESSORRECEIVERHARVEST PRESSURE
Part Number 80-1479-3 7/10 295REMOTE MODELSS500/S600/S850/S1000S1400/S1600/S1800XXHEATEXCHANGEREVAPORATORSOLENOIDLINELIQUIDCHECK VALVESERVICERECEIVERC
296 Part Number 80-1479-3 7/10This Page Intentionally Left Blank
Part Number 80-1479-3 7/10 297This Page Intentionally Left Blank
298 Part Number 80-1479-3 7/10
Safety NoticesAs you work on Manitowoc equipment, be sure to pay close attention to the safety notices in this handbook. Disregarding the notices may
30 Part Number 80-1479-3 7/10S Model Quad Evaporator ModelsWATER PUMPSWATER LEVEL PROBEEVAPORATORSWATER TROUGHCONTROL BOXICE DAMPERS
Manitowoc Ice2110 South 26th Street, P.O. Box 1720Manitowoc, WI 54221-1720, USAPh: 920-682-0161 Fax: 920-683-7589Visit us online at: www.manitowocice
Part Number 80-1479-3 7/10 31MaintenanceGeneralClean and sanitize the ice machine every six months for efficient operation. If the ice machine require
32 Part Number 80-1479-3 7/10Cleaning / Sanitizing ProcedureCLEANING PROCEDUREIce machine cleaner is used to remove lime scale and mineral deposits. I
Part Number 80-1479-3 7/10 33Step 3 Remove all ice from the bin.Step 4 Place the toggle switch in the CLEAN position. The water will flow through
34 Part Number 80-1479-3 7/10PARTS REMOVAL FOR CLEANING/SANITIZINGSingle Evaporator Ice MachinesA. Remove the water curtain• Gently flex the curtain
Part Number 80-1479-3 7/10 35Quad Evaporator Ice MachinesA.Remove the water trough shield.• Grasp the water trough shield in the center and the left e
36 Part Number 80-1479-3 7/10ABCDE
Part Number 80-1479-3 7/10 37Step 7 Mix a solution of cleaner and warm water. Depending upon the amount of mineral buildup, a larger quantity of sol
38 Part Number 80-1479-3 7/10Step 12 Use 1/2 of the sanitizer/water solution to sanitize all foodzone surfaces of the ice machine and bin (or dispen
Part Number 80-1479-3 7/10 39Step 15 Reapply power to the ice machine and place the toggle switch in the CLEAN position.Step 16 Wait until the wat
NOTE: Text set off as a Note provides you with simple, but useful, extra information about the procedure you are performing.Read These Before Proceedi
40 Part Number 80-1479-3 7/10Procedure to Clean Heavily Scaled Ice MachinesIce machines that are heavily scaled or have not been cleaned on a regular
Part Number 80-1479-3 7/10 41Ice machine cleaner is used to remove lime scale and mineral deposits. Ice machine sanitizer disinfects and removes algae
42 Part Number 80-1479-3 7/10Step 5 Wait until the clean cycle is complete (approximately *35 minutes). then place the toggle switch in the OFF posi
Part Number 80-1479-3 7/10 43PARTS REMOVAL FOR CLEANING/SANITIZINGSingle Evaporator Ice MachinesA. Remove the water curtain• Gently flex the curtain i
44 Part Number 80-1479-3 7/10E. Remove the water level probe• Pull the water level probe straight down to disengage.• Lower the water level probe unti
Part Number 80-1479-3 7/10 45A.B.C.D.E.F.G.
46 Part Number 80-1479-3 7/10Quad Evaporator Ice MachinesA. Remove panels• Remove both front panels• Remove top panelB. Remove front evaporator shield
Part Number 80-1479-3 7/10 47F. Remove distribution tubes.• Distribution tube thumbscrews are retained to prevent loss. Loosen thumbscrews but do not
48 Part Number 80-1479-3 7/10AABCDEFGHI
Part Number 80-1479-3 7/10 49Step 7 Mix a solution of cleaner and warm water. Depending upon the amount of mineral buildup, a larger quantity of sol
Part Number 80-1479-3 7/10 5Table of ContentsGeneral InformationModel Numbers . . . . . . . . . . . . . . . . . . . . . 9How to Read a Model Number .
50 Part Number 80-1479-3 7/10bin (or dispenser). Use a cloth or sponge to liberally apply the solution. When sanitizing, pay particular attention to t
Part Number 80-1479-3 7/10 51Step 19 Use 1/2 of the sanitizer/water solution to sanitize all removed components. Use a cloth or sponge to liberally
52 Part Number 80-1479-3 7/10Ice Thickness Probe & Water Level ProbeClean the probes using the following procedure.1. Mix a solution of Manitowoc
Part Number 80-1479-3 7/10 53Water Inlet ValveThe water inlet valve normally does not require removal for cleaning. Refer to “Water System Checklist”
54 Part Number 80-1479-3 7/10Water Dump ValveThe water dump valve normally does not require removal for cleaning. To determine if removal is necessary
Part Number 80-1479-3 7/10 55NOTE: During cleaning, do not stretch or damage the spring.1. Remove the tubing from the dump valve by twisting the clamp
56 Part Number 80-1479-3 7/10Drain Line Check ValveThe drain line check valve (not used on all models) should be inspected and cleaned, whenever the i
Part Number 80-1479-3 7/10 57Removal from Service/WinterizationGeneralSpecial precautions must be taken if the ice machine is to be removed from servi
58 Part Number 80-1479-3 7/10WATER-COOLED ICE MACHINES1. Perform steps 1-6 under “Self-Contained Air-Cooled Ice Machines.”2. Disconnect the incoming w
Part Number 80-1479-3 7/10 59Sequence of OperationSelf Contained Air or Water CooledSINGLE & QUAD EVAPORATOR MODELSNOTE: The toggle switch must be
6 Part Number 80-1479-3 7/10Removal from Service/Winterization . . . 57Self-Contained Air-Cooled Ice Machines 57Water-Cooled Ice Machines . . . . .
60 Part Number 80-1479-3 7/10Freeze Sequence3. PrechillThe compressor lowers the temperature of the evaporator(s) before the water pump is energized.
Part Number 80-1479-3 7/10 61Harvest Sequence5. Water PurgeThe air compressor (when used) and the harvest valve(s) open at the beginning of the water
62 Part Number 80-1479-3 7/106. HarvestThe air compressor (when used) remains energized and the harvest valve(s) remains open. The refrigerant gas war
Part Number 80-1479-3 7/10 63Automatic Shut-Off7. Automatic Shut-OffWhen the storage bin is full at the end of a harvest sequence, the sheet of cubes
64 Part Number 80-1479-3 7/10Safety TimersThe control board has the following non-adjustable safety timers:• The ice machine is locked into the freeze
Part Number 80-1479-3 7/10 65Safety LimitsSafety limits are stored and indicated by the control board after three cycles. The number of cycles require
66 Part Number 80-1479-3 7/10Safety Limit Stand-By Mode (Quad Evaporators Only)The first time a safety limit shut down occurs, (three consecutive long
Part Number 80-1479-3 7/10 67Warm Water Rinse CycleSingle evaporator models only - Closing the back of the evaporator allows ice to build up on the re
68 Part Number 80-1479-3 7/10Self Contained Air & Water-Cooled Single Evaporator Model Energized Parts Chart Ice MakingSequence ofOperationWaterPu
Part Number 80-1479-3 7/10 69Harvest Sequence5. Water PurgeOn On On30 sec.Off15 sec.OnOn On OnMay CycleOn/OffFactorySet at 45 Seconds6. HarvestOff On
Part Number 80-1479-3 7/10 7Component Check ProceduresElectrical Components . . . . . . . . . . . . . . . 135Main Fuse . . . . . . . . . . . . . . .
70 Part Number 80-1479-3 7/10Self Contained Water-CooledQuad Evaporator Model Energized Parts Chart Ice MakingSequence ofOperationWaterPumpsHarvestVal
Part Number 80-1479-3 7/10 71Harvest Sequence5. Water PurgeOn On OnOnfrom 30-45 secondsOn On OnFactorySet at 30 Seconds6. HarvestOff On On Off Off On
72 Part Number 80-1479-3 7/10REMOTESSingle Evaporator ModelsNOTE: The toggle switch must be in the ice position and the water curtain must be in place
Part Number 80-1479-3 7/10 732. Refrigeration System Start-UpThe compressor and liquid line solenoid valve energize after the 45 second water purge an
74 Part Number 80-1479-3 7/10Freeze Sequence3. PrechillThe compressor is on for 30 seconds (60 seconds initial cycle) prior to water flow, to prechill
Part Number 80-1479-3 7/10 75Harvest Sequence5. Water PurgeThe water pump continues to run, and the water dump valve energizes for 45 seconds to purge
76 Part Number 80-1479-3 7/10Automatic Shut-Off7. Automatic Shut-OffWhen the storage bin is full at the end of a harvest sequence, the sheet of cubes
Part Number 80-1479-3 7/10 77Remote Air-CooledSingle Evaporator Model Energized Parts Chart Ice MakingSequence ofOperationWaterPumpHarvestValve(Left)H
78 Part Number 80-1479-3 7/10Harvest Sequence5. Water PurgeOn On OnOnAfter 35 sec.30 sec.Off15 sec.OnOn On On OnFactorySet at 45 Seconds6. Harvest Off
Part Number 80-1479-3 7/10 79This Page Intentionally Left Blank
8 Part Number 80-1479-3 7/10ChartsCycle Times/24-Hour Ice Production/Refrigerant Pressure Charts . . . . . . . . . . 191S300 Series . . . . . . . . .
80 Part Number 80-1479-3 7/10This Page Intentionally Left Blank
Part Number 80-1479-3 7/10 81TroubleshootingSafety LimitsIn addition to standard safety controls, the control board has built in safety limit controls
82 Part Number 80-1479-3 7/10QUAD EVAPORATOR MACHINES ONLYWhen a safety limit condition causes the ice machine to stop, the harvest light on the contr
Part Number 80-1479-3 7/10 83Safety Limit Stand-By Mode:The first time a safety limit shut down occurs, (three consecutive long freeze or harvest cycl
84 Part Number 80-1479-3 7/10ANALYZING WHY A SAFETY LIMIT STOPPED THE ICE MACHINEAccording to the refrigeration industry, a high percentage of compres
Part Number 80-1479-3 7/10 85SAFETY LIMIT #1Water System1. Water supply to machine is being interrupted2. Water leaking down the drain during freeze (
86 Part Number 80-1479-3 7/10SAFETY LIMIT #2Water System1. Ice thickness control probe is dirty causing a premature harvest with no ice on the plate.
Part Number 80-1479-3 7/10 87SAFETY LIMIT #3Water System1. Water supply to machine is being interrupted2. Water leaking down the drain during freeze (
88 Part Number 80-1479-3 7/10Control Board TestingAll replacement S Model control boards and ice machines with serial numbers larger than 110924847 ha
Part Number 80-1479-3 7/10 89Troubleshooting By SymptomThe troubleshooting procedures follow flow charts. There are four symptoms, the symptom that yo
Part Number 80-1479-3 7/10 9General InformationModel NumbersThis manual covers the following models: NOTE: Model numbers ending in 3 indicate a 3 ph
90 Part Number 80-1479-3 7/10SYMPTOM #1 ICE MACHINE WILL NOT RUNIce Machine Stops Running or Has a History of Shutting DownYESYESNONOYESNOControl boar
Part Number 80-1479-3 7/10 91YESYESNONOAreWater Curtain/Ice Dampersin place?YESYESSL1/Harvest (once)Run machine &check for Normal OperationRefer t
92 Part Number 80-1479-3 7/10COMPRESSOR ELECTRICAL DIAGNOSTICSThe compressor does not start or will trip repeatedly on overload.Check Resistance (Ohm)
Part Number 80-1479-3 7/10 93CHECK MOTOR WINDINGS TO GROUNDCheck continuity between all three terminals and the compressor shell or copper refrigerati
94 Part Number 80-1479-3 7/10SYMPTOM #2 LOW PRODUCTION, LONG FREEZEIce Machine has a Long Freeze Cycle. Ice Formation is Thick or Thin Ice Fill on Top
Part Number 80-1479-3 7/10 95PROCEDUREStep 1 Complete the “Operation Analysis” column.Read down the left “Operational Analysis” column. Perform all
96 Part Number 80-1479-3 7/10SYMPTOM #2 - FREEZE CYCLE REFRIGERATION SYSTEM OPERATIONAL ANALYSIS TABLESS MODELS SINGLE EXPANSION VALVEOperational Anal
Part Number 80-1479-3 7/10 97Freeze Cycle Suction Pressure_______ ______ _____1 minute Middle EndIf suction pressure is High or Low
98 Part Number 80-1479-3 7/10Wait 5 minutes into the freeze cycle.Compare temperatures of compressor discharge line and harvest valve inlet.The harves
Part Number 80-1479-3 7/10 99Freeze Cycle Refrigeration System Operational Analysis TablesS MODELS DUAL EXPANSION VALVEOperational Analysis 1 2 3 4Ice
Commentaires sur ces manuels