Part Number 80-1479-3 7/10 135
Component Check Procedures
Electrical Components
MAIN FUSE
FUNCTION
The control board fuse stops ice machine operation if
electrical components fail, causing high amp draw.
SPECIFICATIONS
The main fuse is 250 Volt, 7 amp.
CHECK PROCEDURE
1. If the bin switch light is on with the water curtain/
ice dampers closed, the fuse is good.
2. Remove the fuse. Check for continuity across the
fuse with an ohmmeter.
!
Warning
High (line) vo ltage is a pplied to the con trol b oard
(terminals #55 an d #56) at all times. Re moving the
control bo ard fuse or movin g the toggle switch to
OFF wi ll no t re move the po wer sup plied to the
control board.
!
Warning
Disconnect e lectrical p ower to the en tire ice
machine before proceeding.
Reading Result
Open (OL) Replace fuse
Closed (O) Fuse is good