44 Part Number 80-1479-3 7/10
E. Remove the water level probe
Pull the water level probe straight down to
disengage.
Lower the water level probe until the wiring
connector is visible.
Disconnect the wire lead from the water level
probe.
Remove the water level probe from the ice
machine.
F. Remove the water pump.
Grasp pump and pull straight down on pump
assembly until water pump disengages and
electrical connector is visible.
Disconnect the electrical connector.
Remove the water pump assembly from ice
machine.
Do not soak the water pump motor in cleaner or
sanitizer solution.
G. Remove the evaporator tray or water diverter
from the bottom of the evaporator.
Loosen thumbscrew on left side of tray.
Allow left side of tray to drop as you pull the tray to
the left side. Continue until the outlet tube
disengages from the right side.
NOTE: Proceed to page 49, Step 7.