Part Number STH025 2/14 143
FREEZE CYCLE DISCHARGE PRESSURE
LOW CHECKLIST
Improper Installation
Refer to “Installation/Visual Inspection Checklist”
(
page 135)
Air Cooled Condensers
Defective head pressure control valve, won’t
bypass (
page 195)
Defective fan cycle control, stuck closed
(page 185)
Water Cooled Condensers
Water Regulating Valve out of adjustment
Water Regulating Valve Defective
Other
Undercharged
Wrong type of refrigerant
Non-Manitowoc components in system
Liquid line/component restricted