Part Number STH025 2/14 139
One Evaporator, Two TXV 30” Models
Tubing routing for one evaporator with two TXV’s is
different. The evaporator has two inlets and outlets. Fill
pattern varies depending on which circuit is affected,
Extremely Thin at the Evaporator Outlet will first be
visible either 1/4 or 3/4 of the way down the
evaporator.
Extremely Thin at the Evaporator Inlet will show at
the bottom of the evaporator or 1/2 of the way down
depending on the circuit affected.
ICE
Thin at Inlet
Inlet
Outlet
ICE
ICE
ICE
ICE
Inlet
Outlet
Thin at Outlet