74 Part Number 80-01111-9 7/10
SPRAY BAR, WATER PUMP AND HOSE
Remove spray bar clamp and spray bar.
1. Grasp pump and pull straight down until water
pump disengages and electrical connector is
visible.
2. Disconnect the electrical connector.
3. Remove the water pump from ice machine.
4. Remove clamp from hose to remove from pump.
5. Do not submerse the water pump motor in cleaner
or sanitizer. If soaking is required, immerse pump
to normal water level during the freeze.
! Warning
Disconnect the e lectric pow er to the ice machine
at the electric service switch b ox and turn off the
water supply before proceeding.
DO NOT
IMMERSE
MOTOR IN
SOLUTION
REMOVE
CLAMP
REMOVE
CLAMP
MAXIMUM
SOLUTION
HEIGHT WHEN
SOAKING