Manitowoc Q130 Spécifications Page 165

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 236
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 164
Part Number 80-01111-9 7/10 165
1. Remove the back panel to access the bin
thermostat.
2. Disconnect both wires #12 and #1 from the bin
thermostat and check the resistance across the
bin thermostat terminals.
NOTE: After covering/uncovering the bulb holder with
ice, wait at least three minutes to allow the thermostat
to react. (Open/Close)
No Ice on Bulb Ice on Bulb Result
Closed (O) Open (OL) Thermostat good
Open (OL) Closed (O) Replace
thermostat
DECREASE
LEVEL OF
ICE IN BIN
INCREASE
LEVEL OF
ICE IN BIN
1.5"
(3.8 CM)
4"
(10.2 CM)
SV1680B
WARMER
COOLER
Vue de la page 164
1 2 ... 160 161 162 163 164 165 166 167 168 169 170 ... 235 236

Commentaires sur ces manuels

Pas de commentaire