46 Part Number 80-01111-9 7/10
Step 1 Set the toggle switch to the OFF position after
ice falls from the evaporator at the end of a Harvest
cycle. Or, set the switch to the OFF position and allow
the ice to melt off the evaporator.
Step 2 Remove all ice from the bin.
Step 3 To start a cleaning cycle, move the toggle
switch to the WASH position.
Step 4 Add the proper amount of Manitowoc Ice
Machine Cleaner to the water trough.
Step 5 Wait until the clean cycle is complete
(approximately 22 minutes) then place the toggle
switch in the OFF position, disconnect power and
water supplies to the ice machine.
!
Caution
Never use a nything to force ice fro m the
evaporator. Damage may result.
Model Amount of Cleaner
QM45 1.5 ounce (45 ml)
Q130 1 ounce (30 ml)
Q170 2 ounces (60 ml)
Q210 2 ounces (60 ml)
Q270 2 ounces (60 ml)
! Warning
Disconnect electric power to the ice machine
at the electric switch box before proceeding.