Manitowoc QF0800 Spécifications Page 91

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 90
Part Number 80-1230-9 6/08 91
Water Dump Valve
The water dump valve normally does not require
removal for cleaning. To determine if removal is
necessary:
1. Locate the water dump valve.
2. Set the toggle switch to ICE.
3. While the ice machine is in the freeze mode,
check the drain for leakage.
If the dump valve is leaking, remove, disassemble
and clean it.
If the dump valve is not leaking, do not remove it.
Instead, follow the “Cleaning Procedure”.
Follow the procedure below to disassemble the dump
valve.
4. Leaving the wires attached, press down and twist
the coil 1/8 turn, then lift the coil assembly off the
valve body.
5. Remove the nylon washer, plunger, and
diaphragm.
!
Warning
Disconnect the electric power to the ice machine
at the electric service switch box and turn off the
water supply before proceeding.
Vue de la page 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 307 308

Commentaires sur ces manuels

Pas de commentaire