Part Number 80-1230-9 6/08 87
Float Valve Removal
1. Place the toggle switch in the OFF position, turn
off the water supply and disconnect electrical
power to the ice machine.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure
tube.
6. Remove top cover from float reservoir.
7. Lift float valve out of float reservoir.
Water Reservoir Removal
1. Place the toggle switch in the OFF position and
turn off the water supply to the ice machine at the
water service valve.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Place the toggle switch in the ICE position. The
dump valve will open and the float reservoir will
empty.
4. After the reservoir is empty, place the toggle
switch in the OFF position and disconnect power
to the ice machine at the service disconnect.
5. Remove water float valve coil.
A. Depress coil and rotate 1/4 turn
counterclockwise.
B. With coil wires attached, lift coil off enclosure
tube.
6. Remove top cover from float reservoir.
7. Lift float valve out of float reservoir.
8. Disconnect the drain lines from reservoir.
9. Lift reservoir off of evaporator assembly.