Manitowoc QF0800 Spécifications Page 106

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 105
106 Part Number 80-1230-9 6/08
Water Reservoir Removal
1. Place the toggle switch in the OFF position and turn off
the water supply to the ice machine at the water service
valve.
2. Disconnect water supply line at float valve quick
disconnect by depressing stainless steel lever.
3. Place the toggle switch in the ICE position. The dump
valve will open and the float reservoir will empty.
4. After the reservoir is empty, place the toggle switch in
the OFF position and disconnect power to the ice
machine at the service disconnect.
5. Remove water float valve coil.
6. Depress coil and rotate 1/4 turn counterclockwise.
7. With coil wires attached, lift coil off enclosure tube.
8. QF0800/QC0700 ONLY Rotate quarter turn fasteners
counterclockwise.
9. QF0800/QC0700 ONLY Remove cotter key and pin
from ice chute.
QF2200/QF2300 ONLY Remove cotter key and
retaining pin from water reservoir.
10. Remove top cover from float reservoir.
11. Lift float valve out of float reservoir.
12. Disconnect the drain lines from reservoir.
13. Lift reservoir off of evaporator assembly.
WATER
RESERVOIR
EVAPORATOR
ASSEMBLY
Vue de la page 105