Manitowoc RF0266 Spécifications Page 10

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 156
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 9
10 Part Number 000007661 7/10
Potable Water Requirements
Plumbing must conform to local codes.
Do not connect the ice machine to a hot water
supply. Be sure all hot water restrictors installed for
other equipment are working. (Check valves on
sink faucets, dishwashers, etc.)
If water pressure exceeds maximum pressure
(70 psig [483 kPa] RN1000; 80 psig [552 kPa] for
all other models) obtain a water pressure regulator
from your Manitowoc distributor.
A water shut-off valve is required to clean the ice
machine.
A union for both the ice making and condenser
water lines is required.
Water inlet lines require insulation to prevent
condensation.
RF Models: A backflow preventer is required on
water inlet lines.
Drain Connections
Drain lines must have a 1.5 inch drop per 5 feet of
run (2.5 cm per meter), and must not create traps.
The floor drain must be large enough to
accommodate drainage from all drains.
Separate insulated bin and water-cooled
condenser drain lines are required.
The bin and ice machine drains require a vent.
Vue de la page 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 155 156

Commentaires sur ces manuels

Pas de commentaire