Manitowoc MII 150 Guide de dépannage Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
26
Installation and Service Manual
OPERATION
115V/220V NON ADJUSTABLE AGITATION TIMER
The agitation timer on this unit is equipped with test pins. This allows you to test the timer by removing the jumper
between the two pins. When the jumper is removed the timer will cycle every 55 seconds if it is operating correctly. If the
timer is wired correctly and does not cycle approximately every 55 seconds when the jumper is removed, replacement
of the timer may be necessary. Make sure to replace the jumper pins when finished.
NOTES: This timer is re-settable, timed agitation every 3.5 hours from last dispense on power supply broken. Never
operate in normal mode without test pins in place, damage could occur.
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 47 48

Commentaires sur ces manuels

Pas de commentaire