88 Part Number 000007661 6/12
WTR Light
Flashing?
YES
BT Light On?
Disconnect/Reconnect Power, Replace
Control Board If Ice Machine Will Not Run
NO
YES
NO
YES
20 Minute Time Delay Period
Depress Control Board Reset Button To Override Delay Period
Press Control Board
Reset Button – Flashing
Stops, Gear Motor And
Compressor Energize
Determine Cause Of Water LossYes
No
Compressor (C)
Light On?
Compressor Switch
In On Position?
Move Switch
To On Position
Check For Line
Voltage @ Control
Board Compressor
Terminals
Disconnect
Switch From
Control Board
Replace Rocker Switch
Replace Control BoardNo Line Voltage
Line Voltage