Part Number 000007661 6/12 39
Removal from Service/Winterization
Follow the procedure below.
1. Disconnect the electric power at the circuit
breaker or the electric service switch.
2. Turn off the water supply.
3. Disconnect and drain the incoming ice-making
water line at the rear of the ice machine.
4. Disconnect drain tubing and drain water into
container and discard.
5. Make sure water is not trapped in any of the water
or drain lines.
6. Water cooled - Use compressed air to remove all
water from the condenser.
!
Caution
If water is allowed to remain in the ice machine in
freezing temperatures, severe damage to some
components could result. Damage of this nature is
not covered by the warranty.