68 Part Number 000007661 6/12
Bin Thermostat
Closed?
NO
Replace Thermostat
YES
Ice Contacting
Thermostat?
Remove Ice - Allow
To Warm And Retest
Adjusting Closes
Thermostat?
Verify New Setting Cycles
Machine On/Off
YES
NO NO
YES
YES
Chute Switch
Closed?
NO
Adjust Or Replace
Actuator
Ice Contacting
Actuator?
Remove Ice And
Retest
Actuator Functions?
Replace SwitchYES
NO NO
YES
Yes
YES
Reservoir Full Of
Water?
NO
Restore Water Supply / Replace Water Inlet Valve
Power To Water
Inlet Valve?
YES
Water Level
Switch Closed?
NO NO
Repair Wiring
Replace Switch or
Float Assembly