Part Number 80-1230-9 10/10 47
NOTE: Periodic cleaning must be performed on
adjacent surface areas not contacted by the water
distribution system.
Manitowoc recommends disassembling, cleaning and
sanitizing the ice machine and bin/dispenser a
minimum of once every six months.
Step 5
A. The ice machine may be set to start and
finish a cleaning procedure, and then
automatically start ice making again.
B. Wait about one minute into the cleaning cycle
(until the Dump Valve light de-energizes),
then move the switch from CLEAN to ICE
position.
When the cleaning cycle is complete, the Flush light
will turn off and ice making will start automatically.