Manitowoc SM50 Spécifications Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
Ice Machine Operation Section 3
3-2
Part Number 000001590
Control Panel
FUNCTIONS
Power Button (Green)
Pressing the “Power” button once will energize the ice
machine and green Power light. Pressing the “Power”
button a second time will de-energize the ice machine.
Automatic Ice Making Light (Blue)
This light is energized when the ice machine is the ice
making position. The light is off when the ice machine is
in the clean cycle.
Delay Start
Pressing the “Delay Start” button will initiate a delay
cycle. The ice machine will not run until the delay time
expires.
Pressing the button once will energize the 2 hour
light and initiate a two hour delay period.
Pressing the button a second time will energize the 4
hour light and initiate a four hour delay period.
Pressing the button a third time will energize the 8
hour light and initiate an eight hour delay period.
Pressing the button a fourth time will cancel the delay
cycle.
Clean (Green)
Pressing the “Clean” button will initiate a clean cycle and
de-energize the “Automatic Ice Making” light. The clean
light will flash during the clean cycle to indicate the
proper time to add ice machine cleaner or sanitizer.
Replace Filter (Red)
When the ice machine completes 8000 freeze/harvest
cycles the light will energize to indicate the filter needs
replacement. Depressing the “Clean” button for 6
seconds will reset the counter and de-energize the light.
SAFETY TIMERS
The control board has the following non-adjustable
safety timers:
Initial cycle is 5 minutes longer than subsequent
cycles.
The ice machine is locked into the freeze cycle for 10
minutes (15 minutes initial cycle) before a harvest
cycle can be initiated.
The maximum freeze time is 120 minutes at which
time the control board automatically initiates a
harvest cycle (step 4).
The maximum harvest time is 5 minutes at which
time the control board automatically start a freeze
cycle.
Power
Delay
Start
24
8
Hours
Clean
Replace
Water Filter
To reset:
Push and hold Clean button
for 6 seconds.
Automatic
Ice
Making
Vue de la page 21