Section 4 Maintenance
Part Number 000001759 4-5
Step 16 The ice machine will stop after the sanitize
cycle (approximately 30 minutes). Place the toggle
switch in the OFF position and disconnect power to the
ice machine.
Step 17 Repeat step 6 for hand sanitizing.
Step 18 Mix a solution of sanitizer and warm water.
Step 19 Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge
to liberally apply the solution to all surfaces of the
removed parts or soak the removed parts in the
sanitizer/water solution. Do not rinse parts after
sanitizing.
Step 20 Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin
(or dispenser). Use a cloth or sponge to liberally apply
the solution. When sanitizing, pay particular attention to
the following areas:
Side walls
Base (bottom of the water trough)
Interior of water trough
Evaporator cells and evaporator plastic parts -
including top, bottom and sides
Bin or dispenser
Ice machine top cover
Do not rinse the sanitized areas. Remove the water
trough drain plug and wipe with solution. When the
sanitizer solution has drained from the trough, reinstall
the water trough drain plug.
Step 21 Install the removed parts, restore power and
place the toggle switch in the ICE position.
!
Warning
Disconnect the electric power to the ice machine at
the electric service switch box..
Solution Type Water Mixed With
Sanitizer 23 l 120 ml sanitizer